First Person Vision 学術論文(J)

高速楕円検出に基づく眼球回旋運動のリアルタイム計測システム

Author
坂下祐輔, 藤吉弘亘, 平田豊, 高丸尚教, 深谷直樹
Publication
電気学会論文誌, vol. 127–C pp. 591–598, 2007

This paper presents a method for real-time cycloduction measurement based on fast ellipse detection. The Hough transform frame work is known to be effective for ellipse fitting, but most of existing methods need a high computation cost. We therefore present a novel technique for detecting a region of the pupil by fitting an ellipse based on parallelogram. Since our method eliminates outliers due to lighting, it is possible to obtain the ellipse parameters in high accuracy. Once the ellipse parameter for pupil image is detected, we can generate a projected image of iris pattern, and then estimate a rotation angle of the cycloduction by SAD matching considering the temporal information. Our experimental results demonstrate the effectiveness and robustness of our method.